NFC Anti-metal label for high temperature application
Increased improvement of mobile NFC system;
Production can flesible;
Increased magnetic field convergence by relative magnetic permeability
Type:Ferrite sheet
Effective carrier frequency:13.56MHZ and below
Operating temperature(.C):-30.C to +85.C
Permeability(@13.56MHZ) ̡:43.2395
Surface resistivity():>=108R
Heat conductivity(W/m.k):1.0 W/m.k
Adhesive Tape:Customization Optional
Color:Black
Test device :HP4285A;
The information and statements here are believed to be reliable but are not to be construed as a warranty or representation for which we assume legal responsibility.
Users should undertake sufficient verification and testing to determine the suitability for their own particular purpose of any information or products referred to herein.
Item code | Dimenssion(mm) | Cover thickness(mm) | Adhesive thickness(mm) | Total thickness(mm) | Tolerance(mm) |
---|---|---|---|---|---|
IVF-N012-A1T-300x200 | Roll maximum 250mmx20m or sheet customilzed | customilzed | 0.015/ 0.03 | 0.12 | 0.01 |
IVF-N023-A2T-300x200 | Roll maximum 250mmx20m or sheet customilzed | customilzed | 0.015/ 0.03 | 0.23 | 0.01 |
IVF-N030-A2T-300x200 | Roll maximum 250mmx20m or sheet customilzed | customilzed | 0.015/ 0.03 | 0.3 | 0.01 |
IVF-N045-A2T-300x200 | Roll maximum 250mmx20m or sheet customilzed | customilzed | 0.015/ 0.03 | 0.45 | 0.01 |
IVF-N060-A2T-300x200 | Roll maximum 250mmx20m or sheet customilzed | customilzed | 0.015/ 0.03 | 0.60 | 0.01 |
No. | ITEM | TEST CONDITION | TEST REQUIREMENTS |
---|---|---|---|
1 | High Temperature Resistance | 1. Temperature : +85 5 2. Time : 96 hrs 3. Measure after left for 60 min. at room |
1. No visual damage 2. Permeability change within 15% |
2 | Low Temperature Resistance | 1. Temperature : -40 5 2. Time : 96 hrs 3. Measure after left for 60 min. t room |
1. No visual damage 2. Permeability change within 15% |
3 | Humidity(Steady Condition) | 1. Humidity : 80 % RH 2. Temperature : +80 3 3. Time : 120 hrs 4. Measure after left for 60 min. at room |
1. No visual damage 2. Permeability change within 15% |
The information and statements here are believed to be reliable but are not to be construed as a warranty or representation for which we assume legal responsibility.